Review




Structured Review

LKC Technologies utas multifocal erg
Current recommended flow diagram for screening of patients on HCQ or CQ. Reproduced from the RCOphth HCQ and CQ screening guidelines. Abbreviations: CQ, chloroquine; eGFR, estimated glomerular filtration rate; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; HVF, Humphrey automated visual field; <t>mfERG,</t> <t>multifocal</t> electroretinography; SD-OCT, spectral-domain optical coherence tomography.
Utas Multifocal Erg, supplied by LKC Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/utas multifocal erg/product/LKC Technologies
Average 90 stars, based on 1 article reviews
utas multifocal erg - by Bioz Stars, 2026-03
90/100 stars

Images

1) Product Images from "Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study"

Article Title: Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study

Journal: BMJ Open Ophthalmology

doi: 10.1136/bmjophth-2024-001898

Current recommended flow diagram for screening of patients on HCQ or CQ. Reproduced from the RCOphth HCQ and CQ screening guidelines. Abbreviations: CQ, chloroquine; eGFR, estimated glomerular filtration rate; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; HVF, Humphrey automated visual field; mfERG, multifocal electroretinography; SD-OCT, spectral-domain optical coherence tomography.
Figure Legend Snippet: Current recommended flow diagram for screening of patients on HCQ or CQ. Reproduced from the RCOphth HCQ and CQ screening guidelines. Abbreviations: CQ, chloroquine; eGFR, estimated glomerular filtration rate; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; HVF, Humphrey automated visual field; mfERG, multifocal electroretinography; SD-OCT, spectral-domain optical coherence tomography.

Techniques Used: Filtration, Tomography

Schedule of activities
Figure Legend Snippet: Schedule of activities

Techniques Used:

Study participant flow diagram. Abbreviations: ERG, electroretinography; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; mfERG, multifocal electroretinography; OCT, optical coherence tomography.
Figure Legend Snippet: Study participant flow diagram. Abbreviations: ERG, electroretinography; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; mfERG, multifocal electroretinography; OCT, optical coherence tomography.

Techniques Used: Tomography



Similar Products

90
LKC Technologies utas multifocal erg
Current recommended flow diagram for screening of patients on HCQ or CQ. Reproduced from the RCOphth HCQ and CQ screening guidelines. Abbreviations: CQ, chloroquine; eGFR, estimated glomerular filtration rate; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; HVF, Humphrey automated visual field; <t>mfERG,</t> <t>multifocal</t> electroretinography; SD-OCT, spectral-domain optical coherence tomography.
Utas Multifocal Erg, supplied by LKC Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/utas multifocal erg/product/LKC Technologies
Average 90 stars, based on 1 article reviews
utas multifocal erg - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
LKC Technologies multifocal erg (mferg, lkc utas e3000
Ocular features of patient 1. a Ultra wide-field pseudocolor images showing retinal atrophy in the mid and far periphery combined with significant bone spicule-like pigmentation and mottling in both eyes. b SD-OCT shows small macular cysts in the inner nuclear layer, a thickened retina, and an atrophic photoreceptor layer with preservation of the ellipsoid zone (EZ) and the external limiting membrane (ELM). c Visual field shows peripheral visual field loss, with small central loss. <t>d</t> <t>mfERG</t> shows that amplitudes in the posterior-pole of both eyes were significantly reduced, more seriously in the right eye
Multifocal Erg (Mferg, Lkc Utas E3000, supplied by LKC Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/multifocal erg (mferg, lkc utas e3000/product/LKC Technologies
Average 90 stars, based on 1 article reviews
multifocal erg (mferg, lkc utas e3000 - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

Image Search Results


Current recommended flow diagram for screening of patients on HCQ or CQ. Reproduced from the RCOphth HCQ and CQ screening guidelines. Abbreviations: CQ, chloroquine; eGFR, estimated glomerular filtration rate; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; HVF, Humphrey automated visual field; mfERG, multifocal electroretinography; SD-OCT, spectral-domain optical coherence tomography.

Journal: BMJ Open Ophthalmology

Article Title: Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study

doi: 10.1136/bmjophth-2024-001898

Figure Lengend Snippet: Current recommended flow diagram for screening of patients on HCQ or CQ. Reproduced from the RCOphth HCQ and CQ screening guidelines. Abbreviations: CQ, chloroquine; eGFR, estimated glomerular filtration rate; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; HVF, Humphrey automated visual field; mfERG, multifocal electroretinography; SD-OCT, spectral-domain optical coherence tomography.

Article Snippet: Three groups of 35 participants on HCQ, categorised by HCQ retinopathy (definite, possible and no retinopathy), and 35 healthy control participants, recruited by consecutive sampling, will have full field and multifocal ERG index tests, delivered using skin-contact electrodes by two devices—RETEval full-field and UTAS multifocal ERG, both manufactured by LKC Technologies (Gaithersburg, Maryland, USA), compared with spectral-domain optical coherence tomography and autofluorescence reference tests graded by two masked, independent retinal specialists.

Techniques: Filtration, Tomography

Schedule of activities

Journal: BMJ Open Ophthalmology

Article Title: Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study

doi: 10.1136/bmjophth-2024-001898

Figure Lengend Snippet: Schedule of activities

Article Snippet: Three groups of 35 participants on HCQ, categorised by HCQ retinopathy (definite, possible and no retinopathy), and 35 healthy control participants, recruited by consecutive sampling, will have full field and multifocal ERG index tests, delivered using skin-contact electrodes by two devices—RETEval full-field and UTAS multifocal ERG, both manufactured by LKC Technologies (Gaithersburg, Maryland, USA), compared with spectral-domain optical coherence tomography and autofluorescence reference tests graded by two masked, independent retinal specialists.

Techniques:

Study participant flow diagram. Abbreviations: ERG, electroretinography; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; mfERG, multifocal electroretinography; OCT, optical coherence tomography.

Journal: BMJ Open Ophthalmology

Article Title: Novel electroretinography devices to detect hydroxychloroquine retinopathy: study protocol for a diagnostic accuracy and feasibility study

doi: 10.1136/bmjophth-2024-001898

Figure Lengend Snippet: Study participant flow diagram. Abbreviations: ERG, electroretinography; FAF, fundus autofluorescence; HCQ, hydroxychloroquine; mfERG, multifocal electroretinography; OCT, optical coherence tomography.

Article Snippet: Three groups of 35 participants on HCQ, categorised by HCQ retinopathy (definite, possible and no retinopathy), and 35 healthy control participants, recruited by consecutive sampling, will have full field and multifocal ERG index tests, delivered using skin-contact electrodes by two devices—RETEval full-field and UTAS multifocal ERG, both manufactured by LKC Technologies (Gaithersburg, Maryland, USA), compared with spectral-domain optical coherence tomography and autofluorescence reference tests graded by two masked, independent retinal specialists.

Techniques: Tomography

Ocular features of patient 1. a Ultra wide-field pseudocolor images showing retinal atrophy in the mid and far periphery combined with significant bone spicule-like pigmentation and mottling in both eyes. b SD-OCT shows small macular cysts in the inner nuclear layer, a thickened retina, and an atrophic photoreceptor layer with preservation of the ellipsoid zone (EZ) and the external limiting membrane (ELM). c Visual field shows peripheral visual field loss, with small central loss. d mfERG shows that amplitudes in the posterior-pole of both eyes were significantly reduced, more seriously in the right eye

Journal: Orphanet Journal of Rare Diseases

Article Title: Expanding the clinical and genetic spectrum of Heimler syndrome

doi: 10.1186/s13023-019-1243-x

Figure Lengend Snippet: Ocular features of patient 1. a Ultra wide-field pseudocolor images showing retinal atrophy in the mid and far periphery combined with significant bone spicule-like pigmentation and mottling in both eyes. b SD-OCT shows small macular cysts in the inner nuclear layer, a thickened retina, and an atrophic photoreceptor layer with preservation of the ellipsoid zone (EZ) and the external limiting membrane (ELM). c Visual field shows peripheral visual field loss, with small central loss. d mfERG shows that amplitudes in the posterior-pole of both eyes were significantly reduced, more seriously in the right eye

Article Snippet: Both patients underwent a full ophthalmic examination, including best corrected Snellen visual acuity testing (BCVA), color vision (Ishihara color plate), slit lamp biomicroscopy, tonometry, dilated fundus examination, ultrasound biomicroscopy (UBM), A/B-ultrasound (MD-300 L; MEDA Co., Ltd., Tianjin, China), wide-field fundus imaging (Optos PLC, Dunfermline, United Kingdom), spectral domain optical coherence tomography (SD-OCT, Spectralis HRA + OCT, Heidelberg, Engineering Inc., Heidelberg, Germany), full-field electroretinography (ERG, according to the standards of the International Society for Clinical Electrophysiology of Vision; available at www.iscev.org ), multifocal ERG (mfERG, LKC Utas E3000 LKC Technologies Inc., USA), and visual field (Humphrey Visual Field Analyzer, Carl Zeiss Inc., CA, USA).

Techniques: Preserving

Ocular features of patient 2. a Ultra wide-field pseudocolor images showing retinal atrophy in the mid and far periphery combined with significant bone spicule-like pigmentation, mottling in both eyes. b SD-OCT shows bilateral cystoid macular edema, which mainly involved the outer nuclear layer (ONL). The foveal and peripheral macular ellipsoid zone (EZ) was disrupted and almost absent. c Visual field shows peripheral visual field loss except for the superior nasal quadrant. d mfERG shows undetectable rod ERG, subnormal bright flash ERG, and subnormal and delayed cone ERG

Journal: Orphanet Journal of Rare Diseases

Article Title: Expanding the clinical and genetic spectrum of Heimler syndrome

doi: 10.1186/s13023-019-1243-x

Figure Lengend Snippet: Ocular features of patient 2. a Ultra wide-field pseudocolor images showing retinal atrophy in the mid and far periphery combined with significant bone spicule-like pigmentation, mottling in both eyes. b SD-OCT shows bilateral cystoid macular edema, which mainly involved the outer nuclear layer (ONL). The foveal and peripheral macular ellipsoid zone (EZ) was disrupted and almost absent. c Visual field shows peripheral visual field loss except for the superior nasal quadrant. d mfERG shows undetectable rod ERG, subnormal bright flash ERG, and subnormal and delayed cone ERG

Article Snippet: Both patients underwent a full ophthalmic examination, including best corrected Snellen visual acuity testing (BCVA), color vision (Ishihara color plate), slit lamp biomicroscopy, tonometry, dilated fundus examination, ultrasound biomicroscopy (UBM), A/B-ultrasound (MD-300 L; MEDA Co., Ltd., Tianjin, China), wide-field fundus imaging (Optos PLC, Dunfermline, United Kingdom), spectral domain optical coherence tomography (SD-OCT, Spectralis HRA + OCT, Heidelberg, Engineering Inc., Heidelberg, Germany), full-field electroretinography (ERG, according to the standards of the International Society for Clinical Electrophysiology of Vision; available at www.iscev.org ), multifocal ERG (mfERG, LKC Utas E3000 LKC Technologies Inc., USA), and visual field (Humphrey Visual Field Analyzer, Carl Zeiss Inc., CA, USA).

Techniques: